FRP Cooling Tower Natural Draught NX-SERIES


Frp  Cooling Tower Natural Draught NX-SERIES

  • Structures And Supports:- NX-SERIES Cooling Tower Structures Made From  Standard  M.S.Steel . Standard Hot Dip Galvanising Treated /Epoxy Coated/Frp Lined M.S.Steel  For Long Lasting Life And Perform In Water  . Enough Thickness M.S.Steel Provide Ultimate Tensile Strength Strucutre And Support Withstand In  Wind Force.
  • Header/Branchpipes:- NX-SERIES Cooling Tower Header Made Of G.I.Pipes And Branch Pipes For Long Durability.We Can Provide Frp Lined Polymer Pipe For Long Life.
  • Nozzles And Spray Arrangment:- High Grade Polymer Like Nylon-6 And Other Equavalent Rawgoods Uses In Nozzles .Nozzles Design To Water Spashing In Mist And Gives Super Performance
  • Louvers & Fibre Works:- Louvers Made From Premium Grade Fibre Raw Materials Gives Strength And Long Lasting.Gelcoated Surface Ensure Protect Uv Rays And Worse Weather.Louvers Thickness Made Tough Enough To Rest On Cooling Tower For More Time.

Advantage Of NX-SERIES Cooling Towers

  • NX-SERIES Cooling Towers Works  On  Natural Air Inlet  And Heat Dissipation Principle
  • NX-SERIES Cooling Tower Require Wind Airflow And Design To Work In Open Space.
  • Louvers Angles Set Maximum Exposure For Air Contact And Less Split Water Near Cooling Towers.
  • No Vibration Of Fan And Motor Rotation Gives Silant Performance To Cooling Tower
  • It Is Design To Less Water Evaporation And Drift Loss 
  • Saves Energy Cost Gives Same Performance
  • No Brekdown Due To Motor Failure
  • Saves Replacement And Repairing Cost
  • Natrual Draught Cooling Tower Works On Natural Principle
  • No Brekdown Due To Choke Or  Clog Fills As No-Fills
  • Gives Same Cooling Performance As No Replacement Or Choked Fills.
  • Enough Thickness Of Louvers Stable In Wind Force.
  • Louvers Angles Gives Great Cooling Without Drift Loss
  • Top Plank Design Eleminates Water Droplets From Nozzles

In Such Cooling Tower Natural Draught Of Air Flowing Through The Natural Flow. The Draft Cooling Towers Type Atmospheric Include Ms Box Odm Shaped Support Structure With Frp Grids. Louvers Enable Atmospheric Air To Pass Through The Tower. In This Type Of Water Cooling Tower System Is Pumped To A Spray Head Gl Always On Top Of A Tower. Is Sprayed Down Into The Tower Through Nozzles, Because The Heat Transfer From Water To Air Depends On The Water Surface Exposed To The Air Flow, Therefore , These Cooling Towers Are Provided With A Nozzle Special Type Spray With Fine Spray Pattern For Good Performance Of The Cooling Tower. These Cooling Towers Should Be Located In Open Space Or The Building In Which The Air Can Fly Freely Through Them.

Available 90 Tr To 200 Tr In Single-Cell &   Unlimited  In Multi-Cell